Functionality
Rotary Blower, DB
The rotary blower DB is equipped with a nozzle tube and the nozzles are directed at the tube banks. By the rotary movement of the nozzle tube during the blowing process the flue gas passes are cleaned from deposits and ashes. The angle of rotation can be adjusted to the boiler situation.
The nozzle tube remains in the flue gas flow and is protected against deflection by means of tube supports.
The material is selected according to the flue gas temperatures.
Rotary blowers clean with steam or air and are applied in smaller boilers with slight fouling and little space.